Septic
Store Home Page
More
Septic Supplies
Alternative
Replacement
Septic Air Pumps For:
Aqua
Safe
Aqua Aire
Cajun
Aire
Hydro-Action
Other
Septic
Air Pumps:
HiBlow
Linear-Best Seller!
Gast Rotary Vane
Secoh Linear
Medo
Piston Series
Alita Linear
Gast
SPP Linear
Regenerative
Blower
Ultra-Air
Aerator
Refurbished Air Pumps:
Refurbished
Linear and Rotary Vane Septic Air Pumps
Septic
Air Pump
Parts & Rebuild Kits:
PARTS HELP GUIDE
Gast
Rotary Vane
Gast SPP Linear
Gast HP Linear
HiBlow HP Linear
Gast DDL Linear
Secoh Linear
Thomas
Linear
Alita Linear
Medo Linear & Piston
Septic
Tank Aerator:
SepAerator™
Submersible
Pumps:
High
Head Effluent Pumps
Sump & Effluent
Pumps
Sewage Pumps
Sewage Packages
Outdoor Pump Stations
Septic
Tank Risers & Lids: Tuf-Tite
Risers & Lids
Polylok Risers & Lids
Washing
Machine Filter:
Filtrol
160 ™ Septic Protector Lint Filter
More
Septic Aeration
System Accessories:
Pump
Housings/Platform
Fake Rock Covers
Septic Tank Risers & Lids
SpaFlex Flexible Airline
Rubber Grommets
Septic
Alarms & Floats:
High
Water Alarms
Control Panels
Float Switches
Septic
Care Products &
Chlorine Tablets:
Aerobic
Bacterium
Root
Killer
Filtrol-160 Septic Protector
Septic Odor Vent Pipe Filter
Septic Chlorine Tablets
DeChlorination Tablets
Remediation Tablets
Chlorination
Devices:
Chlorine
Tablet Feeders
Norweco Tablet Feeders
Distribution
Boxes:
Tuf-Tite
Distribution Boxes
Polylok
Distribution Box
Drainage
Products:
Trench
Drains
Drain
Sump
Septic
Tank Filters:
4"
& 6" Effluent Filters
BK2000
Bio-Kinetic Filters
Septic
& Pump Tanks:
Septic
Tanks
Pump
Tanks
Infiltrator
Chambers:
Infiltrator
Quick 4™
|
Alarm
Details & Specificiations
|
|
Model RAB 202
Power Specifications:
Input power: 120 VAC, 60 Hz, 1 Phase, 20 Amps
Pump: 120 VAC, 20 Amp C/B, 1 Hp max.
Compressor: 120 VAC, 10 Amp C/B, 1/2 Hp max.
Alarm: 120 VAC, 10 Amp C/B, Alarm/Control power.
Control Features:
Pump Control: Pump on/off is controlled by the water level
at the pump float. Includes Pump Test switch to verify operation
of the effluent pump. Individual circuit breakers provide short
circuit protection and disconnect feature for compressor, pump,
and alarm circuit.
Alarm: Visual and audible (90 dB) alarm for High Water
and Low Air Pressure faults. Includes Mute/Test
switch to verify operation of the alarm circuits and to silence
the audible alarm until fault is cleared.
Enclosure: 8”X8”X4”poly enclosure rated
NEMA 4X (waterproof)
Certifications:NSF/ANSI Standard 40 approved UL Listed (UL508A)
Control Panel for USA/Canada
Model 202 System Component Requirements:
High Water Alarm float –Rated 120VAC, 1 Amp min.
Pump float –Rated 120VAC, 20 Amps (1 Hp) min.
Pump –120VAC, 1 Hp Max, UL approved with
internal thermal protection.
Compressor –120VAC, 1/2 Hp Max, UL approved. |
|
| |
|
|
Model RAB 203
Power Specifications:
Input power: 120 VAC, 60 Hz, 1 Phase, 20 Amps
Pump: 120 VAC, 20 Amp C/B, 1 Hp max.
Compressor: 120 VAC, 10 Amp C/B, 1/2 Hp max.
Alarm: 120 VAC, 10 Amp C/B, Alarm/Control power.
Control Features:
Timer Control: Pump on-time is selectable in 15 minute
increments for any combination of times during 24-hour cycle. Override
feature turns pump on immediately if water exceeds normal levels
(during surges or extended power outages).
Includes Pump Test switch to verify operation of the effluent pump.
Individual circuit breakers provide short circuit protection and
disconnect feature for compressor, pump, and alarm circuit.
Alarm: Visual and audible (90 dB) alarm for High Water
and Low Air Pressure faults. Includes Mute/Test
switch to verify operation of the alarm circuits and to silence
the audible alarm until fault is cleared.
Enclosure: 8”X8”X4”poly enclosure rated
NEMA 4X (waterproof)
Certifications:NSF/ANSI Standard 40 approved UL Listed (UL508A)
Control Panel for USA/Canada
Model 203 System Component Requirements:
High Water Alarm float –Rated 120VAC, 1 Amp min.
Override float - Rated 120VAC, 20 Amps (1 Hp) min.
Pump float –Rated 120VAC, 20 Amps (1 Hp) min.
Pump –120VAC, 1 Hp Max, UL approved with internal thermal
protection.
Compressor –120VAC, 1/2 Hp Max, UL approved. |
|
| |
|
|